Download New Updated (Spring 2015) Cisco 350-080 Actual Tests 161-170

Ensurepass  QUESTION 161 Refer to the exhibit. According to the equipment tab in Cisco UCS Manager, which is true?     A. A is an uplink port, B is a fabric port, C is a server port, D is a backplane port, E is a DCE interface, and F is a vNIC B. A is an uplink port, B is a server port, C is a fabric port, D is a backplane port, E is a DCE interface, and F is a vNIC C. A is an uplink port, B is a fabric port, C is a backplane port, D is a server port, E is a DCE interface, Read more […]

Download New Updated (Spring 2015) Cisco 350-080 Actual Tests 151-160

Ensurepass  QUESTION 151 What would be the cause for the following fault in UCS Manager?   “ether VIF x / xxx down, reason: ENM source pinning failed”   A. The associated VLANs of a vNIC are not found on an uplink. B. Overlapping VLAN IDs exist on upstream disjoint networks. C. The vNIC was not configured for fabric failover. D. The vNIC is pinned to the wrong fabric. E. Overlapping VSAN IDs exist on upstream S AN switches. F. The vHBA was not configured for failover. Read more […]

Download New Updated (Spring 2015) Cisco 350-080 Actual Tests 141-150

Ensurepass  QUESTION 141 Given the following output:   san-port-channel 12 is up   Hardware is Fibre Channel   Port WWN is 24:0c:00:0d:ec:d3:5c:00   Admin port mode is NP, trunk mode is on   Port mode is NP   Port vsan is 1   Speed is 8 Gbps   Member[1] : fc2/3   Member[2] : fc2/4   What does “Speed is 8 Gbps” indicate?   A. The speed of the slowest interface in the port channel B. The combined speed of all interfaces configured Read more […]

Download New Updated (Spring 2015) Cisco 350-080 Actual Tests 131-140

Ensurepass  QUESTION 131 When creating a QoS policy dialog box in Cisco UCSM, which four fields can be modified? (Choose four.)   A. name B. best-effort C. burst D. rate E. host control   Correct Answer: ACDE     QUESTION 132 Which policy determines what happens to local data and to the BIOS settings on a server during the discovery process and when the server is disassociated from a service profile?   A. boot policy and BIOS policy B. disk scrub Read more […]

Download New Updated (Spring 2015) Cisco 350-080 Actual Tests 121-130

Ensurepass  QUESTION 121 Why is a Cisco UCS B250 server unable to support 16-GB DIMMs?   A. Dual-rank DIMMs are not supported. B. 16-GB DIMMs are too slow. C. The largest DIMM an Intel 55xx or 56xx CPU can address is 32 GB. D. The memory bus would be too long. E. The blade would run too hot.   Correct Answer: C     QUESTION 122 On a Cisco UCS B250 M2 server that is fully populated with 1333-MHz memory and an E5640 CPU, what is the fastest speed the memory Read more […]

Download New Updated (Spring 2015) Cisco 350-080 Actual Tests 111-120

Ensurepass  QUESTION 111 What are the four vPath packet flow steps? (Choose four.)   A. perform flow lookups B. intercept packets on service enabled ports C. run packets through the vPath flow manager D. classify the packets E. flow manager emits an action for the packets F. enforce the action determined by the flow manager   Correct Answer: BCEF     QUESTION 112 A Cisco switch has this configuration for a port channel connecting to an ESXi using dual Read more […]

Download New Updated (Spring 2015) Cisco 350-080 Actual Tests 101-110

Ensurepass  QUESTION 101 A VSM is actually a virtual machine that requires how many vNICs for functioning?   A. 0 B. 1 C. 2 D. 3 E. 4   Correct Answer: D       QUESTION 102 When configuring vPC-HM CDP with multiple links to the same switch, are port-channels required?     A. Each link between the upstream switch and the VEM is an individual subgroup. B. Connections that go to the same upstream switch must be configured with the command Read more […]

Download New Updated (Spring 2015) Cisco 350-080 Actual Tests 91-100

Ensurepass  QUESTION 91 Which command is used to determine if a host has logged in to the Fibre Channel fabric?   A. show flogi database B. show system fc login C. show npv flogi-table D. show npv fcns database E. show interface vfc X flogi F. show interface flogi   Correct Answer: A     QUESTION 92 Traffic drop for FCoE is experienced across a Nexus 5548 switch. What is a possible cause?   A. Server’s CNA does not support DCBX and PFC TLV was Read more […]