Conducting Cisco Unified Wireless Site Survey V2

Question No: 31

When designing for location services, how many APs should be heard by each location- ready AP and at what dBm signal level? (Choose two.)

  1. At least 1 to 2 APs at a signal level of -67 dBm or better

  2. No more than 3 APs at a signal level of -72 dBm or better

  3. At least 5 to 6 APs at a signal level of -75 dBm or better

  4. At least three and preferably four at a signal level of -75 dBm or better

  5. As many APs as possible at a signal level of -72 dBm or better

Answer: C,D

Question No: 32

An engineer is conducting a passive survey. On what two items will data be collected? (Choose two.)

  1. RF interference

  2. rate shifting data rates

  3. roaming

  4. rouges

  5. encryption

Answer: A,D

Question No: 33 DRAG DROP

Ensurepass 2017 PDF and VCE

Answer:

Ensurepass 2017 PDF and VCE

Question No: 34

A new client has contacted you to design a WLAN solution for a new 30-foot high-bay warehouse that will use high-lift electric forklifts. The warehouse is currently empty except for storage racks. The customer is planning to continue to use their existing wireless barcode scanners and also deploy wireless IP phones for communication. Which four issues do you need to consider prior to performing the site survey? (Choose four.)

  1. Which protocol do the wireless barcode scanners and IP phones need to use?

  2. What is the proximity to other warehouses?

  3. Which types of goods will be stored in the warehouse and what is the expected average warehouse capacity?

  4. Do any planned WLC locations exceed 100 meter cable distances?

  5. Is there sufficient clearance between the roof and the top of the racks for placing APs?

  6. What is the expected humidity level in the warehouse on average during the year?

  7. Are there any secure enclosures that use chain-link fence that will require wireless access?

Answer: A,C,E,G

Question No: 35

An engineer is conducting a site calibration using Cisco WCS. The current network has 802.11a, 802.11b, 802.11g, and 802.11n devices. How many times should the calibration be done?

  1. once for each band

  2. once for each protocol

  3. once per deployment

  4. once using each data collection type

Answer: A

Question No: 36

A customer wants to deploy wireless services inside a 500-seat auditorium. Given the volume of potential users in this condensed area, what is the best option for AP deployment?

  1. place 802.11n APs along the outside edge with dual-band directional antennas

  2. place 802.11n APs along the outside edge with 2.4GHz directional antennas

  3. place 802.11n APs along the outside edge with 5GHz directional antennas

  4. place 802.11n APs in the center with 2.4GHz sector antennas

  5. place 802.11n APs in the center with 5GHz sector antennas

  6. place 802.11n APs in the center with dual-band sector antennas

Answer: B

Question No: 37

Customer requirements and a WLAN site survey require a Cisco 1250 AP operating at full 802.11a/b/g/n located approximately 150 meters from the closest IDF. What is the best solution to provide wireless coverage to this portion of the customer#39;s facility?

  1. At the AP location, install a power drop and a Cisco Aironet Power Injector Media

    Converter (AIR-PWRINJ-1000AF) to power and the Cisco 1250 and extend the Cat 5 link.

  2. Install an external Cisco Mid-Span 802.3af power injection panel in the same rack as the access switch to extend the driven distance of the structured cable plant.

  3. At the AP location, install a power drop and a Cisco Aironet Power Injector Media Converter (AIR-PWRINJ-FIB) for the Cisco 1250. Then connect a Cat 5 cable from the AP to a fiber-optic-to-copper transceiver which connects to a fiber link to the IDF. At the access switch, connect the fiber cable from the AP location to a fiber-optic port on the switch.

  4. At the AP location, install a power drop and a Cisco AIR-PWRINJ4 power adapter for the Cisco 1250. Connect the Cat 5 cable to the AP from the IDF.

  5. At the AP location, install a local power drop and local power supply for the Cisco 1250. Connect the AP through a pair of fiber-optic-to-copper transceivers back to the access layer switch to provide data access.

Answer: E

Question No: 38

A network engineer is conducting an active wireless survey. Which four actions must be performed to ensure a successful survey? (Choose four.)

  1. Use the same AP model for the survey that is used in production.

  2. Point the antenna of the survey laptop towards the access point.

  3. Perform the survey when site is empty.

  4. Place the survey laptop antenna on a pole while surveying.

  5. Look for potential barriers of the propagation of RF signals.

  6. Identify areas that have high user density.

  7. Use the same wireless devices that the customer will use.

Answer: A,E,F,G

Question No: 39

When ordering the software licenses for a Cisco WLAN project, what are the minimum software packages required if the location requires 390 lightweight APs, 100 of which will be used for location services, and a Cisco 3310 MSE?

  1. One 500 AP single server license package for the WCS and one 3000 device license for the MSE.

  2. One 1000 AP single server license package for the WCS and one 500 device license for the MSE.

  3. One 1000 AP single server license package for the WCS and one 3000 device license for the MSE.

  4. One 500 AP single server license package for the WCS and one 1000 device license for the MSE.

  5. One 1000 AP single server license package for the WCS and one 2000 device license for the MSE.

Answer: A

Question No: 40

After having the kick-off meeting for a new site survey project with your customer, which three factors need to be considered prior to beginning a WLAN site survey? (Choose three.)

  1. Will an additional trip to the facility to perform the initial walkthrough be required?

  2. How much time should be allocated to survey the locations for the controllers?

  3. Will any additional regulatory or safety training be required to complete the site survey?

  4. Is access available to all areas of the customer facility where the WLAN is planned to be deployed?

  5. Which types of controllers and switches will be required to fully conduct the site survey in all areas of the customer facility?

  6. Is access available to customer employees so that initial interviews can be performed?

Answer: A,C,D

100% Free Download!
Download Free Demo:642-732 Demo PDF
100% Pass Guaranteed!
Download 2017 EnsurePass 642-732 Full Exam PDF and VCE

EnsurePass ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

2017 EnsurePass IT Certification PDF and VCE

You must be logged in to post a comment.

Proudly powered by WordPress   Premium Style Theme by www.gopiplus.com