Troubleshooting Cisco Unified Computing

Question No: 51

Some of your servers do not have IP connectivity to the upstream network. Which two commands do you use to identify whether a data path is up and running on a switch? (Choose two.)

  1. show platform fwm info hw-stm

  2. show interface brief

  3. show npvflogi-table

  4. show mac-address table

  5. show pinning border-interfaces active

Answer: B,D

Question No: 52

Refer to exhibit. A Cisco UCS admin is troubleshooting an issue with a vNIC not coming up on a blade. When looking at the CLI of the quot;Fabric Interconnectquot;,the admin runs this command to view the status of the interface. Which option describes a possible reason why the interface is stuck in an quot;initializingquot; state?

Ensurepass 2017 PDF and VCE

  1. The service profile is not applied to a blade.

  2. The VLANs defined on the vNIC are not defined on a matching uplink port.

  3. The uplink port is down.

  4. The QoS policy on the vNIC is invalid.

  5. The MTU on the vNIC is higher than the MTU configured in the QoS system class.

Answer: C

Question No: 53

You have blade servers that run VMware ESXi. Which two tasks do you perform to ensure that all of the components in the Cisco UCS environment use jumbo frames? (Choose two.)

  1. Use a QoS policy for the jumbo frames.

  2. Configure the MTU on the vSwitch.

  3. Configure the fabric interconnect to support 9500-byte frames.

  4. Configure the MTU on the vNIC.

  5. Configure a QoS policy on the vSwitch.

Answer: A,B

Question No: 54

Ensurepass 2017 PDF and VCE

Ensurepass 2017 PDF and VCE

Ensurepass 2017 PDF and VCE

Ensurepass 2017 PDF and VCE

What is the FCF-MAC tor this switch?

A. 54:7f:ee:98:9b:39

B. 54:7f:ee:98:9b:40

C. 54:7f:ee:98:9b:41

D. 54:7f:ee:98:9b:42

E. 54:7f:ee:98:9b:43

Answer: E

Question No: 55

How many FSM tasks can run concurrently on a server?

  1. 1

  2. 2

  3. 4

  4. 16

Answer: A

Question No: 56

Which two options are causes for failure of a Cisco C-Series server that is configured to boot from SAN? (Choose two.)

  1. The boot LUN ID is not 0.

  2. The ISCSI target is only available via one via one path through the network.

  3. C-Series does not support boot from SAN.

  4. The KVM dongle is attached to the front of the server with a USB stick installed.

  5. Under the FCoE properties on the vNIC adapter, the FCoE VLAN ID is set to 10.

  6. The boot table for fc0 has not been configured.

Answer: D,F

Question No: 57

A customer is troubleshooting degraded DIMM errors on a Cisco UCS blade server and would like to reset the BMC. What is the correct command sequence to reset the BMC?

  1. UCS1-A# server x/y

    UCS1-A /chassis/server # scope bmc

    UCS1-A /chassis/server/bmc # reset

    UCS1-A /chassis/server/bmc* # commit-buffer

  2. UCS1-A# server scope

    UCS1-A /chassis/server # scope bmc UCS1-A /chassis/server/bmc # reset

    UCS1-A /chassis/server/bmc* # commit-buffer

  3. UCS1-A# scope server x/y

    UCS1-A /chassis/server # scope bmc UCS1-A /chassis/server/bmc # reset

    UCS1-A /chassis/server/bmc* # commit-buffer

  4. UCS1-A# scope server x/y

UCS1-A /chassis/server # scope bmc

UCS1-A /chassis/server/bmc* # commit-buffer

Answer: C

Question No: 58

Which two types of ports are MAC addresses when operating in switch mode? (Choose two.)

  1. uplink

  2. FEX

  3. server

  4. backplane

Answer: A,C

Question No: 59

On a Cisco UCS B-Series data center environment; how many default roles are there when utilizing RBAC for security restriction?

  1. 1

  2. 5

  3. 10

  4. 15

  5. 20

Answer: C

Question No: 60

You are troubleshooting an FCoE SAN boot issue on a Cisco UCS C240 M3 server with a VIC 1225. Which two of these represent the correct way to bind VSAN 11 to interface vfc5 attached to interface Ethernet 1/5? (Choose two.)

  1. 5548UP(config)# int vfc 5

    5548UP(config-if)# bind interface Ethernet1/5 vsan 11

  2. 5548UP(config)# vsan database 5548UP(config-vsan-db)# vsan 11 interface vfc5

  3. 5548UP(config)# interface Ethernet1/5 5548UP(config-if)# bind vsan 11

  4. 5548UP(config)# vsan database

    5548UP(config-vsan-db)# bind interface vfc5 vsan 11

  5. 5548UP(config)# vsan database 5548UP(config-vsan-db)# interface vfc5 vsan 11

  6. 5548UP(config)# vsan database

5548UP(config-vsan-db)# interface Ethernet1/5 vsan 11

Answer: A,B

100% Free Download!
Download Free Demo:642-035 Demo PDF
100% Pass Guaranteed!
Download 2017 EnsurePass 642-035 Full Exam PDF and VCE

EnsurePass ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No